    Function:

    Set Temperature ---- SetT;

    Backlash Temperature-----BackT;

    1. Heating Mode \'H\':

    • When Temperature ≤ SetT - BackT ;Relay conduction, heating equipment begin to work;

    • When Temperature ≥ SetT, Relay disconnect, heating equipment stop work;

    2. Refrigeration mode \'C\':

    • When Temperature ≥ SetT + BackT ;Relay conduction, refrigeration equipment begin to work;

    • When Temperature ≤ SetT ;Relay conduction, refrigeration equipment stop work;

    3. High Temperature Alarm \'ALA\':

    • When Temperature ≥ Alarm Temperature, The system opens the sound and light alarm, and disconnects the relay, any key stops the sound light;

    4. Delay Start 'OPH\':

    • When a normal heating or refrigeration work is done, the system starts to time T, and only after the T≥OPH, the system can carry out the next round of heating or refrigeration work;

    5. Temperature Correction Function OFE(-10.0 ~ 10.0°):

    •    The system will work for a long time and may have deviations that can be corrected by this function, Temperature = Measured + Calibration;

    6. Parameter Remote Read/Set:

    •    The parameters such as setting temperature, backlash temperature and temperature correction can be set through UART.   

    7. Real-time Temperature Report:

    •    If the temperature reporting function is turned on, the product is transmitted to the terminal by the UART at 1s intervals, which facilitates data collection;

    8. Relay enable (default enable):

    • If the relay is disable, the relay remains disconnected;

    9. Restore factory Settings:

    • At the same time press the STOP, set key more than 3S, restore factory settings;